In Standalone Mode, SYSMON continuously monitors the on-chip sensors. Your application is no longer associated with the SYSMON results. Using the JTAG or I2C interface, you can also configure some of the external analog inputs. No instantiation is required to access the DRP interface over JTAG.
The JTAG as well as I2C access is slower as compared to the fabric DRP access. The SYSMON supports transfer up to 400 Kb/s, Standard Mode (SM) and Fast Mode (FM). For using the JTAG interface to access SYSMON, you need to be aware of the IEEE 1149.1 standard, while for I2C access, the knowledge of I2C 2-wire protocol is necessary.
The SYSMON could shut down the device operation if the junction temperature crosses 125 °C (Over Temperature (OT)), where it is still accessible only through JTAG access.